Gillette SPJD-1000 Standby Generator (100kW)
March 28, 2026
Generac Mobile MMG55DF4 Generator (48kW)
March 28, 2026Gillette SPJD-600 Standby Generator (60kW)
Call for PricingRequest a Quote
The Gillette SPJD-600 Standby Generator offers a John Deere diesel engine, single or three phase voltages, and up to 60 kW of power.
SPJD-600 Models
Model
Phase, Voltage,
Power Factor
Standby Rating
kW, kVA, Amps
SPJD-600-1-1
1 Phase, 120/240V,
1.
Or call us: (888) 481-8845
The Gillette SPJD-600 Standby Generator offers a John Deere diesel engine, single or three phase voltages, and up to 60 kW of power.
| Model | Phase, Voltage, Power Factor |
Standby Rating kW, kVA, Amps |
| SPJD-600-1-1 | 1 Phase, 120/240V, 1.0pf |
60kW, 60kVA, 250A |
| SPJD-600-3-2 | 3 Phase, 120/208V, 0.8pf |
60kW, 75kVA, 208A |
| SPJD-600-3-3 | 3 Phase, 120/240V, 0.8pf |
60kW, 75kVA, 181A |
| SPJD-600-3-4 | 3 Phase, 277/480V, 0.8pf |
60kW, 75kVA, 90A |
| SPJD-600-3-5 | 3 Phase, 127/220V, 0.8pf |
60kW, 75kVA, 197A |
| SPJD-600-3-16 | 3 Phase, 346/600V, 0.8pf |
60kW, 75kVA, 72A |
FEATURES
- All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
- Solid state, frequency compensated voltage regulation is standard.
- Deep Sea 7420 digital controller allows programming to basic engine functions in the field. Controller has stop-manual-auto mode and engine shutdowns, signaled by full text LCD indicators. Includes power monitoring, event logging, and hour meter.
- Heavy-duty circuit breaker is standard on all gen-sets.
- Battery tray, cables, straps, and charger included.
- Meets NFPA-110 Level 1 when equipped with the necessary accessories and installed per NFPA standards.
- UL-1446 and UL-2200 certified.
ENCLOSURE OPTIONS
- OPEN STYLE – No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
- LEVEL 2 – Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 71 dBA at 23 ft.
| Enclosure | Dimensions (inches) L x W x H |
Single Phase Weight (lbs) |
Three Phase Weight (lbs) |
| Open Style | 78 x 42 x 49 | 1871 | 1814 |
| Level 2 | 94 x 42 x 53 | 2396 | 2339 |
DIESEL FUEL TANK OPTIONS
- Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
- Available in three sizes: 108 gallons (24 hour runtime), 216 gallons (48 hour runtime) and 324 gallons (72 hour runtime).
- Further descriptions and tank options available here.
- Generator can also be used with customer-supplied fuel tank.
DOWNLOADS
OPTIONS
- Engine Coolant Heater
- Starting Battery Heater Blanket
- 10A Battery Charger Upgrade
- 20A Battery Charger Upgrade
- 600 CCA 12VDC Starting Battery
- Voltage Selector Switch – modular design rotory cam for switchable voltages: 3PH 208/480 and 1PH 120/240
- Emergency Stop Switch – mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- Emergency Stop Switch – mounted in a “Break Glass Station” NEMA 3R small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- NFPA-110 Compliance Package: Includes 16 lamp dual (8) display remote annunciators (choice of flush-mount or surface-mount) and a heavy-duty 10A 12/24 VDC battery charger
- External Permanent Magnet Generator (PMG) for improved motor starting capabilities and un-interrupted excitation power
- External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
- Critical Grade Silencer Upgrade – for average sound level of 77 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
- Hospital Grade Silencer Upgrade – for average sound level of 66 dBA at 23 ft in a Level 2 Enclosure
- R7 Foam Insulation (4-5 dBA sound reduction)
- Paralleling Package
- Stainless Steel Enclosure
- Generator Enclosure Lights
- Liquid Containment Pan – installed under frame base
- Spring Vibration Mounts
- Motorized Dampers
- Isolator Mounting Pads
- Enclosure Space Heater
- Controller Upgrades and Alarm Interfaces
- Asco 300 Automatic Transfer Switch (See Accessories Tab for a partial listing or follow this link for a full listing)
- Five Year Extended Warranty
| Brand | Gillette |
|---|---|
| Weight | Varies – See Enclosure Chart |
| Dimensions | Varies – See Enclosure Chart |
| Voltage | Varies – See Model Chart |
| Engine | John Deere, 4-cycle, 4-cylinder,Turbocharged |
Related products
-
Generac Mobile MDE330 Generator (290kW)
Call for PricingRequest a QuoteThe Generac Mobile MDE330 Diesel Generator offers a Perkins diesel engine, 25 hour runtime at 75% load, and up to 290kW of mobile power. Features a two-position linkboard with switch for 3PH 120/208V and 3PH 277/480V output, plus standard 120/240 single voltage at the convenience receptacles.
-
Winco RP625 Generator (500kW)
Call for PricingRequest a QuoteThe Winco RP625 Mobile Diesel Generator offers a Volvo Penta diesel engine, up to 500 kW of prime power in 120/208VAC or 277/480VAC, standard receptacle panel, and a premium DOT approved trailer.
-
Generac Mobile MDE1140 Generator (1000kW)
Call for PricingRequest a QuoteThe Generac Mobile MDE1140 Diesel Generator is an innovative mobile power solution with dual 570 kVA gensets that allow for independent or synchronized operations.
GENERATOR FEATURES
Two Perkins Turbocharged after-cooled 6-cylinder diesel engines with electronic governing – EPA Tier 4 Final.