Gillette T4D-3000 Prime Generator (300kW)
March 28, 2026
Gillette EVTD-65EK Generator (6.5kW-Diesel-1Ph)
March 28, 2026Gillette T4D-2500 Prime Generator (250kW)
Call for PricingRequest a Quote
The Gillette T4D-2500 Prime Generator offers a Volvo diesel engine, three phase voltages, and up to 250 kW of continuous power.
T4D-2500 Models
Model
Phase, Voltage,
Power Factor
Prime Rating
kW, kVA, Amps
T4D-2500-3-2
3 Phase, 120/208V,
0.8pf
250kW, 312.5kVA,
868A
T4D-2500-3-3
3 Phase, 120/240V,
0.
Or call us: (888) 481-8845
The Gillette T4D-2500 Prime Generator offers a Volvo diesel engine, three phase voltages, and up to 250 kW of continuous power.
| Model | Phase, Voltage, Power Factor |
Prime Rating kW, kVA, Amps |
| T4D-2500-3-2 | 3 Phase, 120/208V, 0.8pf |
250kW, 312.5kVA, 868A |
| T4D-2500-3-3 | 3 Phase, 120/240V, 0.8pf |
250kW, 312.5kVA, 753A |
| T4D-2500-3-4 | 3 Phase, 277/480V, 0.8pf |
250kW, 312.5kVA, 376A |
| T4D-2500-3-5 | 3 Phase, 127/220V, 0.8pf |
250kW, 312.5kVA, 821A |
| T4D-2500-3-16 | 3 Phase, 346/600V, 0.8pf |
250kW, 312.5kVA, 301A |
FEATURES
- Specifically engineered to handle the difficult conditions of remote oil and gas operations, as well as other off grid applications with continuous duty cycles.
- All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
- Solid state, frequency compensated voltage regulation is standard.
- Electronic engine governor for precise isochronous frequency regulation.
- Basler DGC-2020 digital controller offers an integrated gen-set control system for single gen-set applications, and includes generator metering, engine-generator protections, exercise timer, and expansion capabilities. Controller has stop-run-auto mode buttons, menu scroll buttons, and a backlit LCD display.
- Heavy-duty circuit breaker is standard on all gen-sets.
- Battery tray, cables, straps, and charger included.
- UL-1446 certified.
ENCLOSURE OPTIONS
- OPEN STYLE – No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
- LEVEL 2 – Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 83 dBA at 23 ft.
| Enclosure | Dimensions (inches) L x W x H |
Three Phase Weight (lbs) |
| Open Style | 132 x 52 x 65 | 5777 |
| Level 2 | 186 x 72 x 94 | 7547 |
DIESEL FUEL TANK OPTIONS
- Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
- Available in two sizes: 982 gallons (56 hour runtime) and 1959 gallons (113 hour runtime).
- Further descriptions and tank options available here.
- Generator can also be used with customer-supplied fuel tank.
DOWNLOADS
OPTIONS
- Engine Coolant Heater
- Starting Battery Heater Blankets
- 10A Battery Charger Upgrade
- 20A Battery Charger Upgrade
- Two 1000 CCA 12VDC Starting Batteries
- Paralleling Package
- Camlock Connections Panel
- Emergency Stop Switch – mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations
- Emergency Stop Switch – mounted in a “Break Glass Station” NEMA 3R small enclosure, UL Listed, Suitable for remote locations
- External Permanent Magnet Generator (PMG) for improved motor starting capabilities and un-interrupted excitation power
- External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
- Critical Grade Silencer Upgrade – for average sound level of 98 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
- Hospital Grade Silencer Upgrade – for average sound level of 78 dBA at 23 ft in a Level 2 Enclosure
- R7 Foam Insulation (4-5 dBA sound reduction)
- Stainless Steel Enclosure
- Generator Enclosure Lights
- Liquid Containment Pan – installed under frame base
- Spring Vibration Mounts
- Motorized Dampers
- Isolator Mounting Pads
- Enclosure Space Heater
- Controller Upgrades and Alarm Interfaces
- Five Year Extended Warranty
| Brand | Gillette |
|---|---|
| Weight | Varies – See Enclosure Chart |
| Dimensions | Varies – See Enclosure Chart |
| Voltage | Varies – See Model Chart |
| Engine | Volvo, EPA Tier 4 Final, 4-cycle, 6-cylinder, Turbo-After-Cooler, SCR Catalyst, DEF Tank |
Related products
-
Winco W6010KE-18/A Generator (6kW, 3PH, 277V/480V)
Call for PricingRequest a QuoteFree Shipping in the Continental United States
Please call for orders to Alaska or Hawaii.
The Winco W6010KE-18/A Portable Diesel Generator offers a Kohler engine, electric start, and up to 6000 watts of 277V/480V 3 phase power. -
Generac Mobile MDE2900 Generator (2542kW)
Call for PricingRequest a QuoteThe Generac Mobile MDE2900 Diesel Generator is an innovative mobile power solution with four 725 kVA gensets that allow for independent or synchronized operation up to 2900 kVA at 3PH 277/480V 60Hz.
-
Winco WL14000HE Generator (14,000W)
Call for PricingRequest a QuoteFree Shipping in the Continental United States
Please call for orders to Alaska or Hawaii.
The Winco WL14000HE Portable Generator offers a Briggs & Stratton Vanguard engine, electric start, and up to 14 kW of power.






Reviews