Gillette T4D-1500 Prime Generator (150kW)
March 28, 2026
Gillette SP-8000 Standby Generator (800kW)
March 28, 2026Gillette T4D-2000 Prime Generator (200kW)
Call for PricingRequest a Quote
The Gillette T4D-2000 Prime Generator offers a Volvo diesel engine, three phase voltages, and up to 200 kW of continuous power.
T4D-2000 Models
Model
Phase, Voltage,
Power Factor
Prime Rating
kW, kVA, Amps
T4D-2000-3-2
3 Phase, 120/208V,
0.8pf
200kW, 250kVA,
694A
T4D-2000-3-3
3 Phase, 120/240V,
0.
Or call us: (888) 481-8845
The Gillette T4D-2000 Prime Generator offers a Volvo diesel engine, three phase voltages, and up to 200 kW of continuous power.
| Model | Phase, Voltage, Power Factor |
Prime Rating kW, kVA, Amps |
| T4D-2000-3-2 | 3 Phase, 120/208V, 0.8pf |
200kW, 250kVA, 694A |
| T4D-2000-3-3 | 3 Phase, 120/240V, 0.8pf |
200kW, 250kVA, 602A |
| T4D-2000-3-4 | 3 Phase, 277/480V, 0.8pf |
200kW, 250kVA, 301A |
| T4D-2000-3-5 | 3 Phase, 127/220V, 0.8pf |
200kW, 250kVA, 656A |
| T4D-2000-3-16 | 3 Phase, 346/600V, 0.8pf |
200kW, 250kVA, 240A |
FEATURES
- Specifically engineered to handle the difficult conditions of remote oil and gas operations, as well as other off grid applications with continuous duty cycles.
- All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
- Solid state, frequency compensated voltage regulation is standard.
- Electronic engine governor for precise isochronous frequency regulation.
- Basler DGC-2020 digital controller offers an integrated gen-set control system for single gen-set applications, and includes generator metering, engine-generator protections, exercise timer, and expansion capabilities. Controller has stop-run-auto mode buttons, menu scroll buttons, and a backlit LCD display.
- Heavy-duty circuit breaker is standard on all gen-sets.
- Battery tray, cables, straps, and charger included.
- UL-1446 certified.
ENCLOSURE OPTIONS
- OPEN STYLE – No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
- LEVEL 2 – Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 83 dBA at 23 ft.
| Enclosure | Dimensions (inches) L x W x H |
Three Phase Weight (lbs) |
| Open Style | 132 x 52 x 65 | 5777 |
| Level 2 | 162 x 52 x 80 | 7547 |
DIESEL FUEL TANK OPTIONS
- Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
- Available in two sizes: 898 gallons (60 hour runtime) and 1796 gallons (120 hour runtime).
- Further descriptions and tank options available here.
- Generator can also be used with customer-supplied fuel tank.
DOWNLOADS
OPTIONS
- Engine Coolant Heater
- Starting Battery Heater Blankets
- 10A Battery Charger Upgrade
- 20A Battery Charger Upgrade
- 750 CCA 12VDC Starting Battery
- Paralleling Package
- Camlock Connections Panel
- Emergency Stop Switch – mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations
- Emergency Stop Switch – mounted in a “Break Glass Station” NEMA 3R small enclosure, UL Listed, Suitable for remote locations
- External Permanent Magnet Generator (PMG) for improved motor starting capabilities and un-interrupted excitation power
- External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
- Critical Grade Silencer Upgrade – for average sound level of 98 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
- Hospital Grade Silencer Upgrade
- R7 Foam Insulation (4-5 dBA sound reduction)
- Stainless Steel Enclosure
- Generator Enclosure Lights
- Liquid Containment Pan – installed under frame base
- Spring Vibration Mounts
- Motorized Dampers
- Isolator Mounting Pads
- Enclosure Space Heater
- Controller Upgrades and Alarm Interfaces
- Five Year Extended Warranty
| Brand | Gillette |
|---|---|
| Weight | Varies – See Enclosure Chart |
| Dimensions | Varies – See Enclosure Chart |
| Voltage | Varies – See Model Chart |
| Engine | Volvo, EPA Tier 4 Final, 4-cycle, 6-cylinder, Turbo-After-Cooler, SCR Catalyst, DEF Tank |
Related products
-
Generac GP3300i Generator (3300W)
Call for PricingRequest a QuoteThe Generac GP3300i Portable Gasoline Generator offers up to 3300 watts of power for the job site.
FEATURES
Generac 149cc gasoline engine.
Status Lights alert when unit is low on oil, overloaded or ready to use.
Low oil shutdown automatically safeguards engine from damage.
Recoil Pull Start. -
Generac Mobile MDE2900 Generator (2542kW)
Call for PricingRequest a QuoteThe Generac Mobile MDE2900 Diesel Generator is an innovative mobile power solution with four 725 kVA gensets that allow for independent or synchronized operation up to 2900 kVA at 3PH 277/480V 60Hz.
-
Generac Mobile MDE330 Generator (290kW)
Call for PricingRequest a QuoteThe Generac Mobile MDE330 Diesel Generator offers a Perkins diesel engine, 25 hour runtime at 75% load, and up to 290kW of mobile power. Features a two-position linkboard with switch for 3PH 120/208V and 3PH 277/480V output, plus standard 120/240 single voltage at the convenience receptacles.