Gillette GPE-75EH-3-2 Generator (6kW, 3PH, 208V)
March 28, 2026
Gillette SPVD-6000 Standby Generator (600kW)
March 28, 2026Gillette SPMI-8000 Standby Generator (800kW)
Call for PricingRequest a Quote
The Gillette SPMI-8000 Standby Generator offers a Mitsubishi diesel engine, numerous three phase voltage options, and up to 800 kW of power.
SPMI-8000 Models
Model
Phase, Voltage,
Power Factor
Standby Rating
kW, kVA, Amps
SPMI-8000-3-2
3 Phase, 120/208V,
0.
Or call us: (888) 481-8845
The Gillette SPMI-8000 Standby Generator offers a Mitsubishi diesel engine, numerous three phase voltage options, and up to 800 kW of power.
| Model | Phase, Voltage, Power Factor |
Standby Rating kW, kVA, Amps |
| SPMI-8000-3-2 | 3 Phase, 120/208V, 0.8pf |
800kW, 1000kVA, 2779A |
| SPMI-8000-3-3 | 3 Phase, 120/240V, 0.8pf |
800kW, 1000kVA, 2408A |
| SPMI-8000-3-4 | 3 Phase, 277/480V, 0.8pf |
800kW, 1000kVA, 1204A |
| SPMI-8000-3-5 | 3 Phase, 127/220V, 0.8pf |
800kW, 1000kVA, 2627A |
| SPMI-8000-3-16 | 3 Phase, 346/600V, 0.8pf |
800kW, 1000kVA, 963A |
FEATURES
- All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
- Solid state, frequency compensated voltage regulation is standard.
- Basler DGC-2020 digital controller offers an integrated gen-set control system for single gen-set applications, and includes generator metering, engine-generator protections, exercise timer, and expansion capabilities. Controller has stop-run-auto mode buttons, menu scroll buttons, and a backlit LCD display.
- Heavy-duty circuit breaker is standard on all gen-sets.
- Battery tray, cables, straps, and charger included.
- Meets NFPA-110 Level 1 when equipped with the necessary accessories and installed per NFPA standards.
- UL-1446 Certified. UL2200 Listed.
ENCLOSURE OPTIONS
- OPEN STYLE – No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
- LEVEL 2 – Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 88 dBA at 23 ft.
| Enclosure | Dimensions (inches) L x W x H |
Weight (lbs) |
| Open Style | 186 x 82 x 94 | 15,950 |
| Level 2 | 234 x 82 x 110 | 16,440 |
DIESEL FUEL TANK OPTIONS
- Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
- Available in three sizes: 1388, 2775 &4162 gallons for 24, 48, or 72 hours of runtime at full load.
- Further descriptions and tank options available here.
- Generator can also be used with customer-supplied fuel tank.
DOWNLOADS
OPTIONS
- Engine Coolant Heater
- Starting Battery Heater Blankets
- 10A Battery Charger Upgrade
- 20A Battery Charger Upgrade
- Two 1000 CCA 12VDC Starting Batteries
- Emergency Stop Switch – mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- Emergency Stop Switch – mounted in a “Break Glass Station” NEMA 3R small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- NFPA-110 Compliance Package: Includes 16 lamp dual (8) display remote annunciators (choice of flush-mount or surface-mount) and a heavy-duty 10A 12/24 VDC battery charger
- External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
- Critical Grade Silencer Upgrade – for average sound level of 99 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
- Hospital Grade Silencer Upgrade – for average sound level of 82 dBA at 23 ft in a Level 2 Enclosure
- R7 Foam Insulation (4-5 dBA sound reduction)
- Paralleling Package
- Stainless Steel Enclosure
- Generator Enclosure Lights
- Liquid Containment Pan – installed under frame base
- Spring Vibration Mounts
- Motorized Dampers
- Isolator Mounting Pads
- Enclosure Space Heater
- Controller Upgrades and Alarm Interfaces
- Asco 300 Automatic Transfer Switch (See Accessories Tab for a partial listing or follow this link for a full listing)
- Five Year Extended Warranty
| Brand | Gillette |
|---|---|
| Weight | Varies – See Enclosure Chart |
| Dimensions | Varies – See Enclosure Chart |
| Voltage | Varies – See Model Chart |
| Engine | Mitsubishi, 4-cycle, 12-cylinder, Turbo-After-Cooler |
Related products
-
Winco DR400V4 Standby Generator (3PH, 400kW)
Call for PricingRequest a QuoteThe Winco DR400V4 diesel standby generator offers a reliable and durable Volvo engine, a Stamford (Cummins) generator end, and up to 400 kW of power. Available in several three phase voltage models. Open Skid design (POWR-PAK) or with Cabinet Enclosure (SOUND-PAK). Optional fuel tanks available.
-
Winco DE40I4 Prime Generator (35kW)
Call for PricingRequest a QuoteThe Winco DE40I4 Prime Generator offers an Isuzu diesel engine and up to 35.1kW of prime power. Perfect for spray foam, roofing, and agricultural applications.
-
Generac GP3300i Generator (3300W)
Call for PricingRequest a QuoteThe Generac GP3300i Portable Gasoline Generator offers up to 3300 watts of power for the job site.
FEATURES
Generac 149cc gasoline engine.
Status Lights alert when unit is low on oil, overloaded or ready to use.
Low oil shutdown automatically safeguards engine from damage.
Recoil Pull Start.






Reviews