The Gillette SPJD-2100 Standby Generator offers a John Deere diesel engine, single or three phase voltages, and up to 210 kW of power.
SPJD-2100 Models
Model
Phase, Voltage,
Power Factor
Standby Rating
kW, kVA, Amps
SPJD-2100-1-1
1 Phase, 120/240V,
1.
Or call us: (888) 481-8845
The Gillette SPJD-2100 Standby Generator offers a John Deere diesel engine, single or three phase voltages, and up to 210 kW of power.
| Model | Phase, Voltage, Power Factor |
Standby Rating kW, kVA, Amps |
| SPJD-2100-1-1 | 1 Phase, 120/240V, 1.0pf |
210kW, 210kVA, 875A |
| SPJD-2100-3-2 | 3 Phase, 120/208V, 0.8pf |
210kW, 262.5kVA, 729A |
| SPJD-2100-3-3 | 3 Phase, 120/240V, 0.8pf |
210kW, 262.5kVA, 632A |
| SPJD-2100-3-4 | 3 Phase, 277/480V, 0.8pf |
210kW, 262.5kVA, 316A |
| SPJD-2100-3-5 | 3 Phase, 127/220V, 0.8pf |
210kW, 262.5kVA, 690A |
| SPJD-2100-3-16 | 3 Phase, 346/600V, 0.8pf |
210kW, 262.5kVA, 252A |
FEATURES
- All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
- Solid state, frequency compensated voltage regulation is standard.
- Deep Sea 7420 digital controller allows programming to basic engine functions in the field. Controller has stop-manual-auto mode and engine shutdowns, signaled by full text LCD indicators. Includes power monitoring, event logging, and hour meter.
- Heavy-duty circuit breaker is standard on all gen-sets.
- Battery tray, cables, straps, and charger included.
- Meets NFPA-110 Level 1 when equipped with the necessary accessories and installed per NFPA standards.
- UL-1446 and UL-2200 certified.
ENCLOSURE OPTIONS
- OPEN STYLE – No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
- LEVEL 2 – Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 75 dBA at 23 ft.
| Enclosure | Dimensions (inches) L x W x H |
Single Phase Weight (lbs) |
Three Phase Weight (lbs) |
| Open Style | 110 x 48 x 55 | 3709 | 3404 |
| Level 2 | 146 x 48 x 72.5 | 4729 | 4364 |
DIESEL FUEL TANK OPTIONS
- Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
- Available in three sizes: 353, 799, & 1059 gallons for 24, 54, or 72 hours of runtime at full load.
- Further descriptions and tank options available here.
- Generator can also be used with customer-supplied fuel tank.
DOWNLOADS
OPTIONS
- Engine Coolant Heater
- Starting Battery Heater Blanket
- 10A Battery Charger Upgrade
- 20A Battery Charger Upgrade
- 750 CCA 12VDC Starting Battery
- Emergency Stop Switch – mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- Emergency Stop Switch – mounted in a “Break Glass Station” NEMA 3R small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- NFPA-110 Compliance Package: Includes 16 lamp dual (8) display remote annunciators (choice of flush-mount or surface-mount) and a heavy-duty 10A 12/24 VDC battery charger
- External Permanent Magnet Generator (PMG) for improved motor starting capabilities and un-interrupted excitation power
- External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
- Critical Grade Silencer Upgrade – for average sound level of 86 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
- Hospital Grade Silencer Upgrade – for average sound level of 70 dBA at 23 ft in a Level 2 Enclosure
- R7 Foam Insulation (4-5 dBA sound reduction)
- Paralleling Package
- Stainless Steel Enclosure
- Generator Enclosure Lights
- Liquid Containment Pan – installed under frame base
- Spring Vibration Mounts
- Motorized Dampers
- Isolator Mounting Pads
- Enclosure Space Heater
- Controller Upgrades and Alarm Interfaces
- Asco 300 Automatic Transfer Switch (See Accessories Tab for a partial listing or follow this link for a full listing)
- Five Year Extended Warranty
| Brand | Gillette |
|---|---|
| Weight | Varies – See Enclosure Chart |
| Dimensions | Varies – See Enclosure Chart |
| Voltage | Varies – See Model Chart |
| Engine | John Deere, 4-cycle, 6-cylinder,Turbocharged |
Related products
-
Winco WL12000HE-17/A Generator (12,000W, 3PH, 132/230V)
Call for PricingRequest a QuoteFree Shipping in the Continental United States
Please call for orders to Alaska or Hawaii.
The Winco WL12000HE-17/A Portable Generator offers a Honda GX630 engine, electric start, up to 12 kW of 3 phase power at 132/230V, and (3) NEMA 5-20R Duplex and (1) NEMA L21-30R 30A receptacle. -
Winco RP415 Generator (333kW)
Call for PricingRequest a QuoteThe Winco RP415 Mobile Diesel Generator offers a FPT diesel engine, up to 333 kW of power, a 2-position voltage selector switch, standard receptacle panel, and a premium DOT approved trailer.
-
Generac Mobile MDE2900 Generator (2542kW)
Call for PricingRequest a QuoteThe Generac Mobile MDE2900 Diesel Generator is an innovative mobile power solution with four 725 kVA gensets that allow for independent or synchronized operation up to 2900 kVA at 3PH 277/480V 60Hz.






Reviews
There are no reviews yet.