
Gillette SPD-1000 Standby Generator (100kW)
March 28, 2026
Gillette SPD-600 Standby Generator (60kW)
March 28, 2026Gillette SPD-300 Standby Generator (30kW)
Call for PricingRequest a Quote
The Gillette SPD-300 Standby Generator offers a Perkins diesel engine, single or three phase voltages, and up to 30 kW of power.
SPD-300 Models
Model
Phase, Voltage,
Power Factor
Standby Rating
kW, kVA, Amps
SPD-300-1-1
1 Phase, 120/240V,
1.0pf
30kW, 30kVA,
125A
SPD-300-3-2
3 Phase, 120/208V,
0.
Or call us: (888) 481-8845
The Gillette SPD-300 Standby Generator offers a Perkins diesel engine, single or three phase voltages, and up to 30 kW of power.
| Model | Phase, Voltage, Power Factor |
Standby Rating kW, kVA, Amps |
| SPD-300-1-1 | 1 Phase, 120/240V, 1.0pf |
30kW, 30kVA, 125A |
| SPD-300-3-2 | 3 Phase, 120/208V, 0.8pf |
30kW, 37.5kVA, 104A |
| SPD-300-3-3 | 3 Phase, 120/240V, 0.8pf |
30kW, 37.5kVA, 90A |
| SPD-300-3-4 | 3 Phase, 277/480V, 0.8pf |
30kW, 37.5kVA, 45A |
| SPD-300-3-5 | 3 Phase, 127/220V, 0.8pf |
30kW, 37.5kVA, 98A |
| SPD-300-3-16 | 3 Phase, 346/600V, 0.8pf |
30kW, 37.5kVA, 36A |
FEATURES
- All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
- Solid state, frequency compensated voltage regulation is standard.
- Electronic engine governor for precise isochronous frequency regulation.
- Deep Sea 7420 digital controller allows programming to basic engine functions in the field. Controller has stop-manual-auto mode and engine shutdowns, signaled by full text LCD indicators. Includes power monitoring, event logging, and hour meter.
- Heavy-duty circuit breaker is standard on all gen-sets.
- Battery tray, cables, straps, and charger included.
- Meets NFPA-110 Level 1 when equipped with the necessary accessories and installed per NFPA standards.
- UL-1446 and UL-2200 certified.
ENCLOSURE OPTIONS
- OPEN STYLE – No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
- LEVEL 2 – Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 69 dBA at 23 ft.
| Enclosure | Dimensions (inches) L x W x H |
Single Phase Weight (lbs) |
Three Phase Weight (lbs) |
| Open Style | 68 x 36 x 46 | 1369 | 1334 |
| Level 2 | 82 x 36 x 47 | 1919 | 1884 |
DIESEL FUEL TANK OPTIONS
- Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
- Available in two sizes: 67 gallons (24 hour runtime) and 134 gallons (48 hour runtime).
- Further descriptions and tank options available here.
- Generator can also be used with customer-supplied fuel tank.
DOWNLOADS
OPTIONS
- Engine Coolant Heater
- Starting Battery Heater Blanket
- 10A Battery Charger Upgrade
- 20A Battery Charger Upgrade
- 600 CCA 12VDC Starting Battery
- Voltage Selector Switch – modular design rotory cam for switchable voltages: 3PH 208/480 and 1PH 120/240
- Emergency Stop Switch – mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- Emergency Stop Switch – mounted in a “Break Glass Station” NEMA 3R small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- NFPA-110 Compliance Package: Includes 16 lamp dual (8) display remote annunciators (choice of flush-mount or surface-mount) and a heavy-duty 10A 12/24 VDC battery charger
- External Permanent Magnet Generator (PMG) for improved motor starting capabilities and un-interrupted excitation power
- External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
- Critical Grade Silencer Upgrade – for average sound level of 75 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
- Hospital Grade Silencer Upgrade – for average sound level of 66 dBA at 23 ft in a Level 2 Enclosure
- R7 Foam Insulation (4-5 dBA sound reduction)
- Paralleling Package
- Stainless Steel Enclosure
- Generator Enclosure Lights
- Liquid Containment Pan – installed under frame base
- Spring Vibration Mounts
- Motorized Dampers
- Isolator Mounting Pads
- Enclosure Space Heater
- Controller Upgrades and Alarm Interfaces
- Asco 300 Automatic Transfer Switch (See below for a partial listing or follow this link for a full listing)
- Five Year Extended Warranty
| Brand | Gillette |
|---|---|
| Weight | Varies – See Enclosure Chart |
| Dimensions | Varies – See Enclosure Chart |
| Voltage | Varies – See Model Chart |
| Engine | Perkins 404D-22TAG, 4-cylinder, Turbocharged |
Related products
-
Winco DP14000 Generator (14000W)
$4,738.00The Winco DP14000 will not disappoint, producing 14,000 starting Watts and 11,760 running watts. The DYNA Professional line will be a great addition to any work crew or master craftsman’s garage.
-
Winco RP35 Generator (30kW)
Call for PricingRequest a QuoteThe Winco RP35F4 Mobile Diesel Generator offers a FPT diesel engine, up to 30 kW of power, a 3-position voltage selector switch, standard receptacle panel, and a premium DOT approved trailer.
-
Generac GP3300i Generator (3300W)
Call for PricingRequest a QuoteThe Generac GP3300i Portable Gasoline Generator offers up to 3300 watts of power for the job site.
FEATURES
Generac 149cc gasoline engine.
Status Lights alert when unit is low on oil, overloaded or ready to use.
Low oil shutdown automatically safeguards engine from damage.
Recoil Pull Start.





Reviews
There are no reviews yet.